Morphological evaluation of normal human corneal epithelium..

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

  • Niels Ehlers
  • Heegaard, Steffen
  • Jesper Østergaard Hjortdal
  • Anders Ivarsen
  • Kim Nielsen
  • Jan Ulrik Prause
PURPOSE: The human corneal epithelium is usually described as a 50-µm-thick layer of regular stratified squamous non-keratinized cells with a thickness of 5-7 cells. The purpose of this study is systemically to revisit the histopathological appearance of 100 corneas.

METHODS: 5-µm-thick sections of corneas from 100 consecutively selected paraffin-embedded eyes were stained with hematoxylin-eosin and Periodic Acid-Schiff (PAS). All specimens were evaluated by light microscopy. The eyes were enucleated from patients with choroidal melanoma. Corneas were considered to be normal.

RESULTS: Ninety of 100 eyes were evaluated. The central epithelial, stromal and total corneal thickness was measured as 36.0 µm, 618 µm and 651µm, respectively, with a variation coefficient from 0.21 to 0.22. Pathological appearances were found in 27% of corneas, including thickened basement membrane and alterations in Bowman's membrane. No intraepithelial microcysts, as found in Meesmann corneal dystrophy, were observed.

CONCLUSION: The total corneal thickness was higher than reported in in vivo studies and with a wider variation. This may be an effect of uncontrolled swelling and dehydration during preparation. The high number of pathological observations suggests that 'normal' eyes harbour and potentially accumulate considerable pathology.

OriginalsprogEngelsk
TidsskriftActa Ophthalmologica
Vol/bind88
Udgave nummer8
Sider (fra-til)858-861
Antal sider4
ISSN1755-375X
DOI
StatusUdgivet - dec. 2010

ID: 33977050