Long-term outcomes following transcatheter aortic valve implantation with the Portico self-expanding valve

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Dokumenter

  • Fulltext

    Forlagets udgivne version, 713 KB, PDF-dokument

  • Arturo Giordano
  • Silvia Mas-Peiro
  • Stephan Fichtlscherer
  • Andreas Schaefer
  • Martin Beyer
  • Francesco Maisano
  • Guido Ascione
  • Nicola Buzzatti
  • Rui Teles
  • João Brito
  • Francisco Albuquerque
  • Maarten Vanhaverbeke
  • Angelo Quagliana
  • Giuliano Costa
  • Marco Barbanti
  • Paolo Ferraro
  • Alberto Morello
  • Michele Cimmino
  • Michele Albanese
  • Martino Pepe
  • Luca Bardi
  • Salvatore Giordano
  • Antonio Cittadini
  • Nicola Corcione
  • Giuseppe Biondi-Zoccai
Aim
Transcatheter aortic valve implantation (TAVI) is a mainstay in the management of severe aortic valve stenosis in elderly patients, but there is uncertainty on their long-term effectiveness. We aimed to assess the long-term outcome of patients undergoing TAVI with the Portico valve.

Methods
We retrospectively collected the data on patients in whom TAVI with Portico was attempted from 7 high-volume centres. Only patients theoretically eligible for 3 or more years of follow-up were included. Clinical outcomes, including death, stroke, myocardial infarction, reintervention for valve degeneration and hemodynamic valve performance were systematically assessed.

Results
A total of 803 patients were included, with 504 (62.8%) women, mean age of 82 years, median EuroSCORE II of 3.1%, and 386 (48.1%) subjects at low/moderate risk. The median follow-up was 3.0 years (3.0; 4.0). The composite of death, stroke, myocardial infarction, and reintervention for valve degeneration occurred in 37.5% (95% confidence interval: 34.1–40.9%), with all-cause death in 35.1% (31.8–38.4%), stroke in 3.4% (1.3–3.4%), myocardial infarction in 1.0% (0.3–1.5%), and reintervention for valve degeneration in 1.1% (0.6–2.1%). The mean aortic valve gradient at follow-up was 8.1 ± 4.6 mmHg, and at least moderate aortic regurgitation was present in 9.1% (6.7–12.3%). Independent predictors of major adverse events or death were: peripheral artery disease, chronic obstructive pulmonary disease, estimated glomerular filtration rate, atrial fibrillation, prior pacemaker implantation, EuroSCORE II, and reduced left ventricular ejection fraction (all p < 0.05).

Conclusions
Portico use is associated with favorable long-term clinical outcomes. Clinical outcomes were largely impacted by baseline risk factors and surgical risk.
OriginalsprogEngelsk
TidsskriftClinical Research in Cardiology
Vol/bind113
Sider (fra-til)86–93
Antal sider7
ISSN1861-0684
DOI
StatusUdgivet - 2024

Bibliografisk note

Funding Information:
Giuseppe Biondi-Zoccai has consulted for Balmed, Cardionovum, Crannmedical, Eukon, Innovheart, Guidotti, Meditrial, Microport, Opsens Medical, Replycare, Teleflex, and Terumo. Andreas Schaefer received speaker honoraria from Abbott. Lars Sondergaard has received consultant fees and institutional research grants from Abbott. All other authors report no conflict of interest.

Publisher Copyright:
© 2023, The Author(s).

ID: 363358195