Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve Disease
Publikation: Bidrag til tidsskrift › Tidsskriftartikel › Forskning › fagfællebedømt
Standard
Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve Disease. / Mylotte, Darren; Lefevre, Thierry; Søndergaard, Lars; Watanabe, Yusuke; Modine, Thomas; Dvir, Danny; Bosmans, Johan; Tchetche, Didier; Kornowski, Ran; Sinning, Jan-Malte; Thériault-Lauzier, Pascal; O'Sullivan, Crochan J; Barbanti, Marco; Debry, Nicolas; Buithieu, Jean; Codner, Pablo; Dorfmeister, Magdalena; Martucci, Giuseppe; Nickenig, Georg; Wenaweser, Peter; Tamburino, Corrado; Grube, Eberhard; Webb, John G; Windecker, Stephan; Lange, Ruediger; Piazza, Nicolo.
I: Journal of the American College of Cardiology, Bind 64, Nr. 22, 09.12.2014, s. 2330-2339.Publikation: Bidrag til tidsskrift › Tidsskriftartikel › Forskning › fagfællebedømt
Harvard
APA
Vancouver
Author
Bibtex
}
RIS
TY - JOUR
T1 - Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve Disease
AU - Mylotte, Darren
AU - Lefevre, Thierry
AU - Søndergaard, Lars
AU - Watanabe, Yusuke
AU - Modine, Thomas
AU - Dvir, Danny
AU - Bosmans, Johan
AU - Tchetche, Didier
AU - Kornowski, Ran
AU - Sinning, Jan-Malte
AU - Thériault-Lauzier, Pascal
AU - O'Sullivan, Crochan J
AU - Barbanti, Marco
AU - Debry, Nicolas
AU - Buithieu, Jean
AU - Codner, Pablo
AU - Dorfmeister, Magdalena
AU - Martucci, Giuseppe
AU - Nickenig, Georg
AU - Wenaweser, Peter
AU - Tamburino, Corrado
AU - Grube, Eberhard
AU - Webb, John G
AU - Windecker, Stephan
AU - Lange, Ruediger
AU - Piazza, Nicolo
N1 - Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
PY - 2014/12/9
Y1 - 2014/12/9
N2 - BACKGROUND: Limited information exists describing the results of transcatheter aortic valve (TAV) replacement in patients with bicuspid aortic valve (BAV) disease (TAV-in-BAV).OBJECTIVES: This study sought to evaluate clinical outcomes of a large cohort of patients undergoing TAV-in-BAV.METHODS: We retrospectively collected baseline characteristics, procedural data, and clinical follow-up findings from 12 centers in Europe and Canada that had performed TAV-in-BAV.RESULTS: A total of 139 patients underwent TAV-in-BAV with the balloon-expandable transcatheter heart valve (THV) (n = 48) or self-expandable THV (n = 91) systems. Patient mean age and Society of Thoracic Surgeons predicted risk of mortality scores were 78.0 ± 8.9 years and 4.9 ± 3.4%, respectively. BAV stenosis occurred in 65.5%, regurgitation in 0.7%, and mixed disease in 33.8% of patients. Incidence of type 0 BAV was 26.7%; type 1 BAV was 68.3%; and type 2 BAV was 5.0%. Multislice computed tomography (MSCT)-based TAV sizing was used in 63.5% of patients (77.1% balloon-expandable THV vs. 56.0% self-expandable THV, p = 0.02). Procedural mortality was 3.6%, with TAV embolization in 2.2% and conversion to surgery in 2.2%. The mean aortic gradient decreased from 48.7 ± 16.5 mm Hg to 11.4 ± 9.9 mm Hg (p < 0.0001). Post-implantation aortic regurgitation (AR) grade ≥ 2 occurred in 28.4% (19.6% balloon-expandable THV vs. 32.2% self-expandable THV, p = 0.11) but was prevalent in only 17.4% when MSCT-based TAV sizing was performed (16.7% balloon-expandable THV vs. 17.6% self-expandable THV, p = 0.99). MSCT sizing was associated with reduced AR on multivariate analysis (odds ratio [OR]: 0.19, 95% confidence intervals [CI]: 0.08 to 0.45; p < 0.0001). Thirty-day device safety, success, and efficacy were noted in 79.1%, 89.9%, and 84.9% of patients, respectively. One-year mortality was 17.5%. Major vascular complications were associated with increased 1-year mortality (OR: 5.66, 95% CI: 1.21 to 26.43; p = 0.03).CONCLUSIONS: TAV-in-BAV is feasible with encouraging short- and intermediate-term clinical outcomes. Importantly, a high incidence of post-implantation AR is observed, which appears to be mitigated by MSCT-based TAV sizing. Given the suboptimal echocardiographic results, further study is required to evaluate long-term efficacy.
AB - BACKGROUND: Limited information exists describing the results of transcatheter aortic valve (TAV) replacement in patients with bicuspid aortic valve (BAV) disease (TAV-in-BAV).OBJECTIVES: This study sought to evaluate clinical outcomes of a large cohort of patients undergoing TAV-in-BAV.METHODS: We retrospectively collected baseline characteristics, procedural data, and clinical follow-up findings from 12 centers in Europe and Canada that had performed TAV-in-BAV.RESULTS: A total of 139 patients underwent TAV-in-BAV with the balloon-expandable transcatheter heart valve (THV) (n = 48) or self-expandable THV (n = 91) systems. Patient mean age and Society of Thoracic Surgeons predicted risk of mortality scores were 78.0 ± 8.9 years and 4.9 ± 3.4%, respectively. BAV stenosis occurred in 65.5%, regurgitation in 0.7%, and mixed disease in 33.8% of patients. Incidence of type 0 BAV was 26.7%; type 1 BAV was 68.3%; and type 2 BAV was 5.0%. Multislice computed tomography (MSCT)-based TAV sizing was used in 63.5% of patients (77.1% balloon-expandable THV vs. 56.0% self-expandable THV, p = 0.02). Procedural mortality was 3.6%, with TAV embolization in 2.2% and conversion to surgery in 2.2%. The mean aortic gradient decreased from 48.7 ± 16.5 mm Hg to 11.4 ± 9.9 mm Hg (p < 0.0001). Post-implantation aortic regurgitation (AR) grade ≥ 2 occurred in 28.4% (19.6% balloon-expandable THV vs. 32.2% self-expandable THV, p = 0.11) but was prevalent in only 17.4% when MSCT-based TAV sizing was performed (16.7% balloon-expandable THV vs. 17.6% self-expandable THV, p = 0.99). MSCT sizing was associated with reduced AR on multivariate analysis (odds ratio [OR]: 0.19, 95% confidence intervals [CI]: 0.08 to 0.45; p < 0.0001). Thirty-day device safety, success, and efficacy were noted in 79.1%, 89.9%, and 84.9% of patients, respectively. One-year mortality was 17.5%. Major vascular complications were associated with increased 1-year mortality (OR: 5.66, 95% CI: 1.21 to 26.43; p = 0.03).CONCLUSIONS: TAV-in-BAV is feasible with encouraging short- and intermediate-term clinical outcomes. Importantly, a high incidence of post-implantation AR is observed, which appears to be mitigated by MSCT-based TAV sizing. Given the suboptimal echocardiographic results, further study is required to evaluate long-term efficacy.
KW - Aged
KW - Aged, 80 and over
KW - Aortic Valve
KW - Aortic Valve Stenosis
KW - Cohort Studies
KW - Female
KW - Heart Valve Diseases
KW - Humans
KW - Male
KW - Prospective Studies
KW - Registries
KW - Retrospective Studies
KW - Transcatheter Aortic Valve Replacement
KW - Treatment Outcome
U2 - 10.1016/j.jacc.2014.09.039
DO - 10.1016/j.jacc.2014.09.039
M3 - Journal article
C2 - 25465419
VL - 64
SP - 2330
EP - 2339
JO - Journal of the American College of Cardiology
JF - Journal of the American College of Cardiology
SN - 0735-1097
IS - 22
ER -
ID: 137324853