Retrospective longitudinal assessment of ultrasound gout lesions using the OMERACT semi-quantitative scoring system

Research output: Contribution to journalJournal articleResearchpeer-review

OBJECTIVES: The objectives of this study were (i) to evaluate the responsiveness of gout-specific US lesions representing urate deposition in patients receiving treat-to-target urate-lowering therapy using a binary and the OMERACT-defined semi-quantitative scoring systems; (ii) to determine the most responsive US measure for urate deposition and the optimal joint/tendon set for monitoring this. METHODS: US (28 joints, 14 tendons) was performed in microscopically verified gout patients initiating/increasing urate-lowering therapy and repeated after 6 and 12 months. Static images/videos of pathologies were stored and scored binarily and semi-quantitatively for tophus, double contour sign (DC) and aggregates. Lesion scores were calculated at patient level, as were combined crystal sum scores. Responsiveness of lesions-scored binarily and semi-quantitatively-was calculated at both patient and joint/tendon levels. RESULTS: Sixty-three patients underwent longitudinal evaluation. The static images/videos assessed retrospectively showed statistically significant decreases in tophus and DC, when scored binarily and semi-quantitatively, whereas aggregates were almost unchanged during follow-up. The responsiveness of the semi-quantitative tophus and DC sum scores were markedly higher than when using binary scoring. The most responsive measure for urate deposition was a combined semi-quantitative tophus-DC-sum score. A feasible joint/tendon set for monitoring included knee and first-second MTP joints and peroneus and distal patella tendons (all bilateral), representing the most prevalent and responsive sites. CONCLUSION: The OMERACT consensus-based semi-quantitative US gout scoring system showed longitudinal validity with both tophus and DC being highly responsive to treatment when assessed in static images/videos. A responsive US measure for urate deposition and a feasible joint/tendon set for monitoring were proposed and may prove valuable in future longitudinal studies.

Original languageEnglish
JournalRheumatology
Volume61
Issue number12
Pages (from-to)4711-4721
Number of pages11
ISSN1462-0324
DOIs
Publication statusPublished - 2022

Bibliographical note

Publisher Copyright:
© The Author(s) 2022. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For permissions, please email: journals.permissions@oup.com.

    Research areas

  • aggregates, double contour, gout, longitudinal validity, monitoring, OMERACT, tophus, ultrasound

ID: 329302917