The impact of continuous wireless monitoring on adverse device effects in medical and surgical wards: a review of current evidence

Research output: Contribution to journalReviewResearchpeer-review

Novel technologies allow continuous wireless monitoring systems (CWMS) to measure vital signs and these systems might be favorable compared to intermittent monitoring regarding improving outcomes. However, device safety needs to be validated because uncertain evidence challenges the clinical implementation of CWMS. This review investigates the frequency of device-related adverse events in patients monitored with CWMS in general hospital wards. Systematic literature searches were conducted in PubMed and Embase. We included trials of adult patients in general hospital wards monitored with CWMS. Our primary outcome was the frequency of unanticipated serious adverse device effects (USADEs). Secondary outcomes were adverse device effects (ADEs) and serious adverse device effects (SADE). Data were extracted from eligible studies and descriptive statistics were applied to analyze the data. Seven studies were eligible for inclusion with a total of 1485 patients monitored by CWMS. Of these patients, 54 patients experienced ADEs (3.6%, 95% CI 2.8–4.7%) and no USADEs or SADEs were reported (0%, 95% CI 0–0.31%). The studies of the SensiumVitals® patch, the iThermonitor, and the ViSi Mobile® device reported 28 (9%), 25 (5%), and 1 (3%) ADEs, respectively. No ADEs were reported using the HealthPatch, WARD 24/7 system, or Coviden Alarm Management. Current evidence suggests that CWMS are safe to use but systematic reporting of all adverse device effects is warranted.

Original languageEnglish
JournalJournal of Clinical Monitoring and Computing
Volume37
Pages (from-to)7–17
ISSN1387-1307
DOIs
Publication statusPublished - 2023

Bibliographical note

Publisher Copyright:
© 2022, The Author(s), under exclusive licence to Springer Nature B.V.

    Research areas

  • Adverse device effects, Continuous wireless monitoring systems, Device safety, Medical wards, Surgical wards, Unanticipated adverse device effects

ID: 328476726