Comparison of Glycemic Metrics Measured Simultaneously by Intermittently Scanned Continuous Glucose Monitoring and Real-Time Continuous Glucose Monitoring in Pregnant Women with Type 1 Diabetes

Research output: Contribution to journalJournal articleResearchpeer-review

Standard

Comparison of Glycemic Metrics Measured Simultaneously by Intermittently Scanned Continuous Glucose Monitoring and Real-Time Continuous Glucose Monitoring in Pregnant Women with Type 1 Diabetes. / Nørgaard, Sidse Kjærhus; Mathiesen, Elisabeth Reinhardt; Nørgaard, Kirsten; Ringholm, Lene.

In: Diabetes Technology and Therapeutics, Vol. 23, No. 10, 2021, p. 665-672.

Research output: Contribution to journalJournal articleResearchpeer-review

Harvard

Nørgaard, SK, Mathiesen, ER, Nørgaard, K & Ringholm, L 2021, 'Comparison of Glycemic Metrics Measured Simultaneously by Intermittently Scanned Continuous Glucose Monitoring and Real-Time Continuous Glucose Monitoring in Pregnant Women with Type 1 Diabetes', Diabetes Technology and Therapeutics, vol. 23, no. 10, pp. 665-672. https://doi.org/10.1089/dia.2021.0109

APA

Nørgaard, S. K., Mathiesen, E. R., Nørgaard, K., & Ringholm, L. (2021). Comparison of Glycemic Metrics Measured Simultaneously by Intermittently Scanned Continuous Glucose Monitoring and Real-Time Continuous Glucose Monitoring in Pregnant Women with Type 1 Diabetes. Diabetes Technology and Therapeutics, 23(10), 665-672. https://doi.org/10.1089/dia.2021.0109

Vancouver

Nørgaard SK, Mathiesen ER, Nørgaard K, Ringholm L. Comparison of Glycemic Metrics Measured Simultaneously by Intermittently Scanned Continuous Glucose Monitoring and Real-Time Continuous Glucose Monitoring in Pregnant Women with Type 1 Diabetes. Diabetes Technology and Therapeutics. 2021;23(10):665-672. https://doi.org/10.1089/dia.2021.0109

Author

Nørgaard, Sidse Kjærhus ; Mathiesen, Elisabeth Reinhardt ; Nørgaard, Kirsten ; Ringholm, Lene. / Comparison of Glycemic Metrics Measured Simultaneously by Intermittently Scanned Continuous Glucose Monitoring and Real-Time Continuous Glucose Monitoring in Pregnant Women with Type 1 Diabetes. In: Diabetes Technology and Therapeutics. 2021 ; Vol. 23, No. 10. pp. 665-672.

Bibtex

@article{677030db87b44e2882b119197bda4b19,
title = "Comparison of Glycemic Metrics Measured Simultaneously by Intermittently Scanned Continuous Glucose Monitoring and Real-Time Continuous Glucose Monitoring in Pregnant Women with Type 1 Diabetes",
abstract = "Background: We aimed to compare clinically important glycemic metrics with focus on mean sensor glucose and time-below-target range (TBR) during nighttime obtained with intermittently scanned continuous glucose monitoring (isCGM) and real-time CGM (rtCGM) in early pregnancy in women with type 1 diabetes. Materials and Methods: A prospective, observational study including 20 women with type 1 diabetes simultaneously monitored with isCGM (Freestyle Libre; Abbott) and rtCGM (Envision{\texttrademark} Pro; Medtronic) for 7 days in early pregnancy. Time-in-target range (TIR) was defined as 3.5-7.8 mmol/L. Results: Gestational age was median 66 (interquartile range 63-74) days and HbA1c was 48 mmol/mol (43-54). Median difference between isCGM and rtCGM was 0.1 mmol/L (-0.1 to 0.5) (P = 0.50) and -0.1 mmol/L (-0.4 to 0.2) (P = 0.35) for 24 h and during nighttime, respectively. For 24 h, TBR was 3.9% (1.6-7.0) versus 2.0% (0.6-3.7) (P = 0.06) and TIR was 57.2% (50.8-76.5) versus 69.6% (55.4-81.5) (P = 0.001) for isCGM and rtCGM, respectively. During nighttime TBR was 6.5% (0.4-16.7) versus 0% (0.0-0.8) (P = 0.003), TIR was 55.4 (41.1-81.0) versus 68.8 (52.4-80.3) (P = 0.005) and 75% versus 40% of the women had ≥1 glucose reading <3.5 mmol/L. Conclusions: In pregnant women with type 1 diabetes, mean sensor glucose was reported similar when measured by isCGM and rtCGM. However, during nighttime isCGM measured a clinically relevant higher percentage of TBR compared with rtCGM. Thus, the type of CGM device used may influence adjustments of insulin dose based on the concern for nocturnal hypoglycemia. ClinicalTrials.gov (NCT03770767). ",
keywords = "Glycemic metrics, Intermittently scanned CGM, Pregnancy, Real-time CGM, Time-below-target range, Type 1 diabetes",
author = "N{\o}rgaard, {Sidse Kj{\ae}rhus} and Mathiesen, {Elisabeth Reinhardt} and Kirsten N{\o}rgaard and Lene Ringholm",
note = "Publisher Copyright: {\textcopyright} Copyright 2021, Mary Ann Liebert, Inc., publishers 2021.",
year = "2021",
doi = "10.1089/dia.2021.0109",
language = "English",
volume = "23",
pages = "665--672",
journal = "Diabetes Technology & Therapeutics",
issn = "1520-9156",
publisher = "Mary AnnLiebert, Inc. Publishers",
number = "10",

}

RIS

TY - JOUR

T1 - Comparison of Glycemic Metrics Measured Simultaneously by Intermittently Scanned Continuous Glucose Monitoring and Real-Time Continuous Glucose Monitoring in Pregnant Women with Type 1 Diabetes

AU - Nørgaard, Sidse Kjærhus

AU - Mathiesen, Elisabeth Reinhardt

AU - Nørgaard, Kirsten

AU - Ringholm, Lene

N1 - Publisher Copyright: © Copyright 2021, Mary Ann Liebert, Inc., publishers 2021.

PY - 2021

Y1 - 2021

N2 - Background: We aimed to compare clinically important glycemic metrics with focus on mean sensor glucose and time-below-target range (TBR) during nighttime obtained with intermittently scanned continuous glucose monitoring (isCGM) and real-time CGM (rtCGM) in early pregnancy in women with type 1 diabetes. Materials and Methods: A prospective, observational study including 20 women with type 1 diabetes simultaneously monitored with isCGM (Freestyle Libre; Abbott) and rtCGM (Envision™ Pro; Medtronic) for 7 days in early pregnancy. Time-in-target range (TIR) was defined as 3.5-7.8 mmol/L. Results: Gestational age was median 66 (interquartile range 63-74) days and HbA1c was 48 mmol/mol (43-54). Median difference between isCGM and rtCGM was 0.1 mmol/L (-0.1 to 0.5) (P = 0.50) and -0.1 mmol/L (-0.4 to 0.2) (P = 0.35) for 24 h and during nighttime, respectively. For 24 h, TBR was 3.9% (1.6-7.0) versus 2.0% (0.6-3.7) (P = 0.06) and TIR was 57.2% (50.8-76.5) versus 69.6% (55.4-81.5) (P = 0.001) for isCGM and rtCGM, respectively. During nighttime TBR was 6.5% (0.4-16.7) versus 0% (0.0-0.8) (P = 0.003), TIR was 55.4 (41.1-81.0) versus 68.8 (52.4-80.3) (P = 0.005) and 75% versus 40% of the women had ≥1 glucose reading <3.5 mmol/L. Conclusions: In pregnant women with type 1 diabetes, mean sensor glucose was reported similar when measured by isCGM and rtCGM. However, during nighttime isCGM measured a clinically relevant higher percentage of TBR compared with rtCGM. Thus, the type of CGM device used may influence adjustments of insulin dose based on the concern for nocturnal hypoglycemia. ClinicalTrials.gov (NCT03770767).

AB - Background: We aimed to compare clinically important glycemic metrics with focus on mean sensor glucose and time-below-target range (TBR) during nighttime obtained with intermittently scanned continuous glucose monitoring (isCGM) and real-time CGM (rtCGM) in early pregnancy in women with type 1 diabetes. Materials and Methods: A prospective, observational study including 20 women with type 1 diabetes simultaneously monitored with isCGM (Freestyle Libre; Abbott) and rtCGM (Envision™ Pro; Medtronic) for 7 days in early pregnancy. Time-in-target range (TIR) was defined as 3.5-7.8 mmol/L. Results: Gestational age was median 66 (interquartile range 63-74) days and HbA1c was 48 mmol/mol (43-54). Median difference between isCGM and rtCGM was 0.1 mmol/L (-0.1 to 0.5) (P = 0.50) and -0.1 mmol/L (-0.4 to 0.2) (P = 0.35) for 24 h and during nighttime, respectively. For 24 h, TBR was 3.9% (1.6-7.0) versus 2.0% (0.6-3.7) (P = 0.06) and TIR was 57.2% (50.8-76.5) versus 69.6% (55.4-81.5) (P = 0.001) for isCGM and rtCGM, respectively. During nighttime TBR was 6.5% (0.4-16.7) versus 0% (0.0-0.8) (P = 0.003), TIR was 55.4 (41.1-81.0) versus 68.8 (52.4-80.3) (P = 0.005) and 75% versus 40% of the women had ≥1 glucose reading <3.5 mmol/L. Conclusions: In pregnant women with type 1 diabetes, mean sensor glucose was reported similar when measured by isCGM and rtCGM. However, during nighttime isCGM measured a clinically relevant higher percentage of TBR compared with rtCGM. Thus, the type of CGM device used may influence adjustments of insulin dose based on the concern for nocturnal hypoglycemia. ClinicalTrials.gov (NCT03770767).

KW - Glycemic metrics

KW - Intermittently scanned CGM

KW - Pregnancy

KW - Real-time CGM

KW - Time-below-target range

KW - Type 1 diabetes

U2 - 10.1089/dia.2021.0109

DO - 10.1089/dia.2021.0109

M3 - Journal article

C2 - 34086494

AN - SCOPUS:85112656538

VL - 23

SP - 665

EP - 672

JO - Diabetes Technology & Therapeutics

JF - Diabetes Technology & Therapeutics

SN - 1520-9156

IS - 10

ER -

ID: 304474549