Preoperative proximal tibial bone density, bone microarchitecture, and bone turnover are not associated with postoperative tibial component migration in cemented and cementless medial unicompartmental knee replacements: secondary analyses from a randomized controlled trial

Research output: Contribution to journalJournal articleResearchpeer-review

Documents

  • Fulltext

    Final published version, 1.99 MB, PDF document

  • Mathias Alrø Fichtner Bendtsen
  • Odgaard, Anders
  • Frank Madsen
  • Sebastian Breddam Mosegaard
  • Jesper Skovhus Thomsen
  • Ellen Margrethe Hauge
  • Kjeld Søballe
  • Maiken Stilling

Background and purpose — Cementless arthroplasty fixation relies on early bone ingrowth and may be poor in patients with low proximal tibial bone density or abnormal bone turnover. We aimed first to describe the baseline bone properties in patients undergoing medial unicompartmen-tal knee replacement (UKR), and second to investigate its association with cemented and cementless tibial component migration until 2 years. Methods — A subset investigation of 2 patient groups from a 3-armed randomized controlled trial was conducted. There were 26 cemented and 25 cementless medial UKRs with twin-pegged femoral components. Volumetric bone mineral density (vBMD) and microstructure of the excised medial tibial plateau were ascertained with µCT. Bone turnover was estimated using dynamic histomorphometry (eroded surface/bone surface = ES/BS, osteoid surface/bone surface = OS/BS, mineralizing surface/bone surface = MS/ BS). Tibial component migration in 4 feature points was followed for 2 years with radiostereometry. Results — At the 2-year follow-up, the cementless tibial components migrated 0.38 mm (95% confidence interval [CI] 0.14–0.62) total translation more than the cemented components at the posterior feature point. The greatest migration in the cementless group was subsidence at the posterior feature point of 0.66 mm (CI 0.48–0.84) until 6 weeks, and from 3 months the components were stable. Cemented tibial components subsided very little. Between 1-and 2-year follow-ups, no cementless but 4 cemented tibial components revealed continuous migration. OS/BS was half of the ES/BS. No µCT or histomorpho-metric parameters showed any clinically relevant correlation with tibial component migration at the posterior feature point for either cemented or cementless UKR at 6 weeks’ or 2 years’ follow-up after adjustment for age, BMI, and sex. Conclusion — Preoperative vBMD, bone turnover, and microstructure were not associated with postoperative tibial component migration of cemented and cementless medial UKR.

Original languageEnglish
JournalActa Orthopaedica
Volume95
Pages (from-to)121-129
Number of pages9
ISSN1745-3674
DOIs
Publication statusPublished - 2024

Bibliographical note

Publisher Copyright:
© 2024 The Author(s). Published by MJS Publishing – Medical Journals Sweden, on behalf of the Nordic Orthopedic Federation.

ID: 385231729