Objective This study assessed differences between fully- and partially-threaded screws in the initial interfragmentary compression strength. Our hypothesis was that there would be an increased loss in initial compression strength with the partially-threaded screw. Methods A 45-degree oblique fracture line was created in artificial bone samples. The first group (FULL, n = 6) was fixed using a 3.5-mm fully-threaded lag screw, while the second group (PARTIAL, n = 6) used a 3.5-mm partially-threaded lag screw. Torsional stiffness for both rotational directions were evaluated. The groups were compared based on biomechanical parameters: angle-moment-stiffness, time-moment- stiffness, maximal torsional moment (failure load), and calibrated compression force based on pressure sensor measurement. Results After loss of one PARTIAL sample, no statistically significant differences in calibrated compression force measurement were observed between both groups: [median (interquartile range)] FULL: 112.6 (10.5) N versus PARTIAL: 106.9 (7.1) N, Mann-Whitney U-test: p = 0.8). In addition, after exclusion of 3 samples for mechanical testing (FULL n = 5, PARTIAL n = 4), no statistically significant differences were observed between FULL and PARTIAL constructs in angle-moment-stiffness, timemoment-stiffness, nor maximum torsional moment (failure load). Conclusion There is no apparent difference in the initial compression strength (compression force or construct stiffness or failure load) achieved using either fullyor partially-threaded screws in this biomechanicalmodel in high-density artificial bone. Fully-threaded screws could, therefore, be more useful in diaphyseal fracture treatment. Further research on the impact in softer osteoporotic, or metaphyseal bone models, and to evaluate the clinical significance is required.

Translated title of the contributionIs there a Difference in Interfragmentary Compression Strength between Fullyor Partially Threaded Screws? Results of an Experimental Biomechanical Pilot Study
Original languageEnglish
JournalRevista Brasileira de Ortopedia
Volume58
Issue number02
Pages (from-to)231-239
ISSN0102-3616
DOIs
Publication statusPublished - 2023

Bibliographical note

Publisher Copyright:
© 2022 Elsevier Editora Ltda. All rights reserved.

    Research areas

  • Biomechanical phenomena, bone cements, bone screws, fractures, bone

ID: 345017892