Patient-Specific Computer Simulation of Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve Morphology

Research output: Contribution to journalJournal articleResearchpeer-review

  • Cameron Dowling
  • Alessandra M. Bavo
  • Nahid El Faquir
  • Peter Mortier
  • Peter De Jaegere
  • De Backer, Ole
  • Søndergaard, Lars
  • Philipp Ruile
  • Darren Mylotte
  • Hannah McConkey
  • Ronak Rajani
  • Jean Claude Laborde
  • Stephen J. Brecker

Background: A patient-specific computer simulation of transcatheter aortic valve replacement (TAVR) in tricuspid aortic valve has been developed, which can predict paravalvular regurgitation and conduction disturbance. We wished to validate a patient-specific computer simulation of TAVR in bicuspid aortic valve and to determine whether patient-specific transcatheter heart valve (THV) sizing and positioning might improve clinical outcomes. Methods: A retrospective study was performed on TAVR in bicuspid aortic valve patients that had both pre-and postprocedural computed tomography imaging. Preprocedural computed tomography imaging was used to create finite element models of the aortic root. Finite element analysis and computational fluid dynamics was performed. The simulation output was compared with postprocedural computed tomography imaging, cineangiography, echocardiography, and electrocardiograms. For each patient, multiple simulations were performed, to identify an optimal THV size and position for the patient's specific anatomic characteristics. Results: A total of 37 patients were included in the study. The simulations accurately predicted the THV frame deformation (minimum-diameter intraclass correlation coefficient, 0.84; maximum-diameter intraclass correlation coefficient, 0.88; perimeter intraclass correlation coefficient, 0.91; area intraclass correlation coefficient, 0.91), more than mild paravalvular regurgitation (area under the receiver operating characteristic curve, 0.86) and major conduction abnormalities (new left bundle branch block or high-degree atrioventricular block; area under the receiver operating characteristic curve, 0.88). When compared with the implanted THV size and implant depth, optimal patient-specific THV sizing and positioning reduced simulation-predicted paravalvular regurgitation and markers of conduction disturbance. Conclusions: Patient-specific computer simulation of TAVR in bicuspid aortic valve may predict the development of important clinical outcomes, such as paravalvular regurgitation and conduction abnormalities. Patient-specific THV sizing and positioning may improve clinical outcomes of TAVR in bicuspid aortic valve.

Original languageEnglish
Article numbere009178
JournalCirculation: Cardiovascular Imaging
Volume12
Number of pages10
ISSN1941-9651
DOIs
Publication statusPublished - 2019

    Research areas

  • aortic valve, bicuspid aortic valve, finite element analysis, humans, transcatheter aortic valve replacement

Number of downloads are based on statistics from Google Scholar and www.ku.dk


No data available

ID: 240988623