A common variant of staphylococcal cassette chromosome mec type IVa in isolates from Copenhagen, Denmark, is not detected by the BD GeneOhm methicillin-resistant Staphylococcus aureus assay

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Standard

A common variant of staphylococcal cassette chromosome mec type IVa in isolates from Copenhagen, Denmark, is not detected by the BD GeneOhm methicillin-resistant Staphylococcus aureus assay. / Bartels, Mette Damkjaer; Boye, Kit; Rohde, Susanne Mie; Larsen, Anders Rhod; Torfs, Herbert; Bouchy, Peggy; Skov, Robert; Westh, Henrik.

I: Journal of Clinical Microbiology, Bind 47, Nr. 5, 2009, s. 1524-7.

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Harvard

Bartels, MD, Boye, K, Rohde, SM, Larsen, AR, Torfs, H, Bouchy, P, Skov, R & Westh, H 2009, 'A common variant of staphylococcal cassette chromosome mec type IVa in isolates from Copenhagen, Denmark, is not detected by the BD GeneOhm methicillin-resistant Staphylococcus aureus assay', Journal of Clinical Microbiology, bind 47, nr. 5, s. 1524-7. https://doi.org/10.1128/JCM.02153-08

APA

Bartels, M. D., Boye, K., Rohde, S. M., Larsen, A. R., Torfs, H., Bouchy, P., Skov, R., & Westh, H. (2009). A common variant of staphylococcal cassette chromosome mec type IVa in isolates from Copenhagen, Denmark, is not detected by the BD GeneOhm methicillin-resistant Staphylococcus aureus assay. Journal of Clinical Microbiology, 47(5), 1524-7. https://doi.org/10.1128/JCM.02153-08

Vancouver

Bartels MD, Boye K, Rohde SM, Larsen AR, Torfs H, Bouchy P o.a. A common variant of staphylococcal cassette chromosome mec type IVa in isolates from Copenhagen, Denmark, is not detected by the BD GeneOhm methicillin-resistant Staphylococcus aureus assay. Journal of Clinical Microbiology. 2009;47(5):1524-7. https://doi.org/10.1128/JCM.02153-08

Author

Bartels, Mette Damkjaer ; Boye, Kit ; Rohde, Susanne Mie ; Larsen, Anders Rhod ; Torfs, Herbert ; Bouchy, Peggy ; Skov, Robert ; Westh, Henrik. / A common variant of staphylococcal cassette chromosome mec type IVa in isolates from Copenhagen, Denmark, is not detected by the BD GeneOhm methicillin-resistant Staphylococcus aureus assay. I: Journal of Clinical Microbiology. 2009 ; Bind 47, Nr. 5. s. 1524-7.

Bibtex

@article{e1c64900ab8611df928f000ea68e967b,
title = "A common variant of staphylococcal cassette chromosome mec type IVa in isolates from Copenhagen, Denmark, is not detected by the BD GeneOhm methicillin-resistant Staphylococcus aureus assay",
abstract = "Rapid tests for detection of methicillin-resistant Staphylococcus aureus (MRSA) carriage are important to limit the transmission of MRSA in the health care setting. We evaluated the performance of the BD GeneOhm MRSA real-time PCR assay using a diverse collection of MRSA isolates, mainly from Copenhagen, Denmark, but also including international isolates, e.g., USA100-1100. Pure cultures of 349 MRSA isolates representing variants of staphylococcal cassette chromosome mec (SCCmec) types I to V and 103 different staphylococcal protein A (spa) types were tested. In addition, 53 methicillin-susceptible Staphylococcus aureus isolates were included as negative controls. Forty-four MRSA isolates were undetectable; of these, 95% harbored SCCmec type IVa, and these included the most-common clone in Copenhagen, spa t024-sequence type 8-IVa. The false-negative MRSA isolates were tested with new primers (analyte-specific reagent [ASR] BD GeneOhm MRSA assay) supplied by Becton Dickinson (BD). The ASR BD GeneOhm MRSA assay detected 42 of the 44 isolates that were false negative in the BD GeneOhm MRSA assay. Combining the BD GeneOhm MRSA assay with the ASR BD GeneOhm MRSA assay greatly improved the results, with only two MRSA isolates being false negative. The BD GeneOhm MRSA assay alone is not adequate for MRSA detection in Copenhagen, Denmark, as more than one-third of our MRSA isolates would not be detected. We recommend that the BD GeneOhm MRSA assay be evaluated against the local MRSA diversity before being established as a standard assay, and due to the constant evolution of SCCmec cassettes, a continuous global surveillance is advisable in order to update the assay as necessary.",
author = "Bartels, {Mette Damkjaer} and Kit Boye and Rohde, {Susanne Mie} and Larsen, {Anders Rhod} and Herbert Torfs and Peggy Bouchy and Robert Skov and Henrik Westh",
note = "Keywords: Carrier State; DNA Primers; Denmark; False Negative Reactions; Genes, Bacterial; Humans; Methicillin-Resistant Staphylococcus aureus; Molecular Diagnostic Techniques; Sensitivity and Specificity; Staphylococcal Infections",
year = "2009",
doi = "10.1128/JCM.02153-08",
language = "English",
volume = "47",
pages = "1524--7",
journal = "Journal of Clinical Microbiology",
issn = "0095-1137",
publisher = "American Society for Microbiology",
number = "5",

}

RIS

TY - JOUR

T1 - A common variant of staphylococcal cassette chromosome mec type IVa in isolates from Copenhagen, Denmark, is not detected by the BD GeneOhm methicillin-resistant Staphylococcus aureus assay

AU - Bartels, Mette Damkjaer

AU - Boye, Kit

AU - Rohde, Susanne Mie

AU - Larsen, Anders Rhod

AU - Torfs, Herbert

AU - Bouchy, Peggy

AU - Skov, Robert

AU - Westh, Henrik

N1 - Keywords: Carrier State; DNA Primers; Denmark; False Negative Reactions; Genes, Bacterial; Humans; Methicillin-Resistant Staphylococcus aureus; Molecular Diagnostic Techniques; Sensitivity and Specificity; Staphylococcal Infections

PY - 2009

Y1 - 2009

N2 - Rapid tests for detection of methicillin-resistant Staphylococcus aureus (MRSA) carriage are important to limit the transmission of MRSA in the health care setting. We evaluated the performance of the BD GeneOhm MRSA real-time PCR assay using a diverse collection of MRSA isolates, mainly from Copenhagen, Denmark, but also including international isolates, e.g., USA100-1100. Pure cultures of 349 MRSA isolates representing variants of staphylococcal cassette chromosome mec (SCCmec) types I to V and 103 different staphylococcal protein A (spa) types were tested. In addition, 53 methicillin-susceptible Staphylococcus aureus isolates were included as negative controls. Forty-four MRSA isolates were undetectable; of these, 95% harbored SCCmec type IVa, and these included the most-common clone in Copenhagen, spa t024-sequence type 8-IVa. The false-negative MRSA isolates were tested with new primers (analyte-specific reagent [ASR] BD GeneOhm MRSA assay) supplied by Becton Dickinson (BD). The ASR BD GeneOhm MRSA assay detected 42 of the 44 isolates that were false negative in the BD GeneOhm MRSA assay. Combining the BD GeneOhm MRSA assay with the ASR BD GeneOhm MRSA assay greatly improved the results, with only two MRSA isolates being false negative. The BD GeneOhm MRSA assay alone is not adequate for MRSA detection in Copenhagen, Denmark, as more than one-third of our MRSA isolates would not be detected. We recommend that the BD GeneOhm MRSA assay be evaluated against the local MRSA diversity before being established as a standard assay, and due to the constant evolution of SCCmec cassettes, a continuous global surveillance is advisable in order to update the assay as necessary.

AB - Rapid tests for detection of methicillin-resistant Staphylococcus aureus (MRSA) carriage are important to limit the transmission of MRSA in the health care setting. We evaluated the performance of the BD GeneOhm MRSA real-time PCR assay using a diverse collection of MRSA isolates, mainly from Copenhagen, Denmark, but also including international isolates, e.g., USA100-1100. Pure cultures of 349 MRSA isolates representing variants of staphylococcal cassette chromosome mec (SCCmec) types I to V and 103 different staphylococcal protein A (spa) types were tested. In addition, 53 methicillin-susceptible Staphylococcus aureus isolates were included as negative controls. Forty-four MRSA isolates were undetectable; of these, 95% harbored SCCmec type IVa, and these included the most-common clone in Copenhagen, spa t024-sequence type 8-IVa. The false-negative MRSA isolates were tested with new primers (analyte-specific reagent [ASR] BD GeneOhm MRSA assay) supplied by Becton Dickinson (BD). The ASR BD GeneOhm MRSA assay detected 42 of the 44 isolates that were false negative in the BD GeneOhm MRSA assay. Combining the BD GeneOhm MRSA assay with the ASR BD GeneOhm MRSA assay greatly improved the results, with only two MRSA isolates being false negative. The BD GeneOhm MRSA assay alone is not adequate for MRSA detection in Copenhagen, Denmark, as more than one-third of our MRSA isolates would not be detected. We recommend that the BD GeneOhm MRSA assay be evaluated against the local MRSA diversity before being established as a standard assay, and due to the constant evolution of SCCmec cassettes, a continuous global surveillance is advisable in order to update the assay as necessary.

U2 - 10.1128/JCM.02153-08

DO - 10.1128/JCM.02153-08

M3 - Journal article

C2 - 19297600

VL - 47

SP - 1524

EP - 1527

JO - Journal of Clinical Microbiology

JF - Journal of Clinical Microbiology

SN - 0095-1137

IS - 5

ER -

ID: 21484615