No effect of hydroxyapatite-coated sliding hip screw threads on screw migration in the femoral head/neck of pertrochanteric fractures: a randomized controlled trial using radiostereometric analysis

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Standard

No effect of hydroxyapatite-coated sliding hip screw threads on screw migration in the femoral head/neck of pertrochanteric fractures : a randomized controlled trial using radiostereometric analysis. / Krogh, August Christoffer; Thillemann, Janni Kjærgaard; Hansen, Torben Bæk; Holck, Kim; Kristensen, Morten Tange; Palm, Henrik; Stilling, Maiken.

I: Journal of Orthopaedic Surgery and Research, Bind 18, Nr. 1, 686, 2023.

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Harvard

Krogh, AC, Thillemann, JK, Hansen, TB, Holck, K, Kristensen, MT, Palm, H & Stilling, M 2023, 'No effect of hydroxyapatite-coated sliding hip screw threads on screw migration in the femoral head/neck of pertrochanteric fractures: a randomized controlled trial using radiostereometric analysis', Journal of Orthopaedic Surgery and Research, bind 18, nr. 1, 686. https://doi.org/10.1186/s13018-023-04170-0

APA

Krogh, A. C., Thillemann, J. K., Hansen, T. B., Holck, K., Kristensen, M. T., Palm, H., & Stilling, M. (2023). No effect of hydroxyapatite-coated sliding hip screw threads on screw migration in the femoral head/neck of pertrochanteric fractures: a randomized controlled trial using radiostereometric analysis. Journal of Orthopaedic Surgery and Research, 18(1), [686]. https://doi.org/10.1186/s13018-023-04170-0

Vancouver

Krogh AC, Thillemann JK, Hansen TB, Holck K, Kristensen MT, Palm H o.a. No effect of hydroxyapatite-coated sliding hip screw threads on screw migration in the femoral head/neck of pertrochanteric fractures: a randomized controlled trial using radiostereometric analysis. Journal of Orthopaedic Surgery and Research. 2023;18(1). 686. https://doi.org/10.1186/s13018-023-04170-0

Author

Krogh, August Christoffer ; Thillemann, Janni Kjærgaard ; Hansen, Torben Bæk ; Holck, Kim ; Kristensen, Morten Tange ; Palm, Henrik ; Stilling, Maiken. / No effect of hydroxyapatite-coated sliding hip screw threads on screw migration in the femoral head/neck of pertrochanteric fractures : a randomized controlled trial using radiostereometric analysis. I: Journal of Orthopaedic Surgery and Research. 2023 ; Bind 18, Nr. 1.

Bibtex

@article{9ffe3902e732468da8f5c17d28f1e702,
title = "No effect of hydroxyapatite-coated sliding hip screw threads on screw migration in the femoral head/neck of pertrochanteric fractures: a randomized controlled trial using radiostereometric analysis",
abstract = "Introduction: Cut-out is the most frequently reported mechanical failure of internal fixation of pertrochanteric fractures. The purpose of this study was to examine if hydroxyapatite-coated screw thread on a sliding hip screw (SHS) could reduce screw migration within the femoral head in patients with stable pertrochanteric fractures. Materials and methods: In a double-blinded randomized controlled study, 37 patients at mean age 78 (range 56–96), with pertrochanteric fracture (Evans I, II, IV) received surgery with a SHS with a hydroxyapatite-coated or a non-coated lag screw thread. Radiostereometry and standard radiographs were obtained 1 day, 6 weeks, 3- and 6 months post-operatively to evaluate screw and fracture migration and fracture reposition. The two groups were combined to describe fracture migration. Results: There was similar and small screw migration in the femoral head between the two groups at 6 weeks, 3- and 6 months (p > 0.12). Fracture migration occurred predominantly in the first 6 weeks, where fracture impaction was 5.95 mm (CI 95% 2.87 to 9.04) and anterior rotation of the femoral head was -2.94° (CI 95% − 5.22 to − 0.66). Migration of the fracture (total translation) correlated to the post-operative fracture reposition (p = 0.002), but not significantly to screw migration (p = 0.09). Neither screw total translation (rho 0.06, p = 0.79) nor fracture total translation (rho 0.04, p = 0.77) correlated with bone mineral density. Conclusion: There was no clinical benefit of hydroxyapatite coating on lag screw migration in this patient cohort. Migration of the pertrochanteric fractures was higher with poor fracture reposition but fractures generally stabilized after 6 weeks follow-up. The study was registered at ClinicalTrials.gov (NCT05677061). Level of evidence II: Patient-blinded prospective randomized study. Trial registration number The study was registered at ClinicalTrials.gov (NCT05677061).",
keywords = "BoneMaster, Hip fracture, Hydroxyapatite, Lag screw, Pertrochanteric fracture, Radiostereometry, Sliding hip screw",
author = "Krogh, {August Christoffer} and Thillemann, {Janni Kj{\ae}rgaard} and Hansen, {Torben B{\ae}k} and Kim Holck and Kristensen, {Morten Tange} and Henrik Palm and Maiken Stilling",
note = "Publisher Copyright: {\textcopyright} 2023, BioMed Central Ltd., part of Springer Nature.",
year = "2023",
doi = "10.1186/s13018-023-04170-0",
language = "English",
volume = "18",
journal = "Journal of Orthopaedic Surgery and Research",
issn = "1749-799X",
publisher = "BioMed Central",
number = "1",

}

RIS

TY - JOUR

T1 - No effect of hydroxyapatite-coated sliding hip screw threads on screw migration in the femoral head/neck of pertrochanteric fractures

T2 - a randomized controlled trial using radiostereometric analysis

AU - Krogh, August Christoffer

AU - Thillemann, Janni Kjærgaard

AU - Hansen, Torben Bæk

AU - Holck, Kim

AU - Kristensen, Morten Tange

AU - Palm, Henrik

AU - Stilling, Maiken

N1 - Publisher Copyright: © 2023, BioMed Central Ltd., part of Springer Nature.

PY - 2023

Y1 - 2023

N2 - Introduction: Cut-out is the most frequently reported mechanical failure of internal fixation of pertrochanteric fractures. The purpose of this study was to examine if hydroxyapatite-coated screw thread on a sliding hip screw (SHS) could reduce screw migration within the femoral head in patients with stable pertrochanteric fractures. Materials and methods: In a double-blinded randomized controlled study, 37 patients at mean age 78 (range 56–96), with pertrochanteric fracture (Evans I, II, IV) received surgery with a SHS with a hydroxyapatite-coated or a non-coated lag screw thread. Radiostereometry and standard radiographs were obtained 1 day, 6 weeks, 3- and 6 months post-operatively to evaluate screw and fracture migration and fracture reposition. The two groups were combined to describe fracture migration. Results: There was similar and small screw migration in the femoral head between the two groups at 6 weeks, 3- and 6 months (p > 0.12). Fracture migration occurred predominantly in the first 6 weeks, where fracture impaction was 5.95 mm (CI 95% 2.87 to 9.04) and anterior rotation of the femoral head was -2.94° (CI 95% − 5.22 to − 0.66). Migration of the fracture (total translation) correlated to the post-operative fracture reposition (p = 0.002), but not significantly to screw migration (p = 0.09). Neither screw total translation (rho 0.06, p = 0.79) nor fracture total translation (rho 0.04, p = 0.77) correlated with bone mineral density. Conclusion: There was no clinical benefit of hydroxyapatite coating on lag screw migration in this patient cohort. Migration of the pertrochanteric fractures was higher with poor fracture reposition but fractures generally stabilized after 6 weeks follow-up. The study was registered at ClinicalTrials.gov (NCT05677061). Level of evidence II: Patient-blinded prospective randomized study. Trial registration number The study was registered at ClinicalTrials.gov (NCT05677061).

AB - Introduction: Cut-out is the most frequently reported mechanical failure of internal fixation of pertrochanteric fractures. The purpose of this study was to examine if hydroxyapatite-coated screw thread on a sliding hip screw (SHS) could reduce screw migration within the femoral head in patients with stable pertrochanteric fractures. Materials and methods: In a double-blinded randomized controlled study, 37 patients at mean age 78 (range 56–96), with pertrochanteric fracture (Evans I, II, IV) received surgery with a SHS with a hydroxyapatite-coated or a non-coated lag screw thread. Radiostereometry and standard radiographs were obtained 1 day, 6 weeks, 3- and 6 months post-operatively to evaluate screw and fracture migration and fracture reposition. The two groups were combined to describe fracture migration. Results: There was similar and small screw migration in the femoral head between the two groups at 6 weeks, 3- and 6 months (p > 0.12). Fracture migration occurred predominantly in the first 6 weeks, where fracture impaction was 5.95 mm (CI 95% 2.87 to 9.04) and anterior rotation of the femoral head was -2.94° (CI 95% − 5.22 to − 0.66). Migration of the fracture (total translation) correlated to the post-operative fracture reposition (p = 0.002), but not significantly to screw migration (p = 0.09). Neither screw total translation (rho 0.06, p = 0.79) nor fracture total translation (rho 0.04, p = 0.77) correlated with bone mineral density. Conclusion: There was no clinical benefit of hydroxyapatite coating on lag screw migration in this patient cohort. Migration of the pertrochanteric fractures was higher with poor fracture reposition but fractures generally stabilized after 6 weeks follow-up. The study was registered at ClinicalTrials.gov (NCT05677061). Level of evidence II: Patient-blinded prospective randomized study. Trial registration number The study was registered at ClinicalTrials.gov (NCT05677061).

KW - BoneMaster

KW - Hip fracture

KW - Hydroxyapatite

KW - Lag screw

KW - Pertrochanteric fracture

KW - Radiostereometry

KW - Sliding hip screw

U2 - 10.1186/s13018-023-04170-0

DO - 10.1186/s13018-023-04170-0

M3 - Journal article

C2 - 37710269

AN - SCOPUS:85171383338

VL - 18

JO - Journal of Orthopaedic Surgery and Research

JF - Journal of Orthopaedic Surgery and Research

SN - 1749-799X

IS - 1

M1 - 686

ER -

ID: 376415128