The impact of co-morbidity burden on appropriate implantable cardioverter defibrillator therapy and all-cause mortality: insight from Danish nationwide clinical registers
Publikation: Bidrag til tidsskrift › Tidsskriftartikel › Forskning › fagfællebedømt
Dokumenter
- The impact of co-morbidity burden on appropriate implantable cardioverter defibrillator therapy and all-cause mortality: insight from Danish nationwide clinical registers
Forlagets udgivne version, 669 KB, PDF-dokument
AIMS: In a nationwide cohort of primary (PP-ICD) and secondary prevention (SP-ICD) implantable cardioverter defibrillator (ICD) patients, we aimed to investigate the association between co-morbidity burden and risk of appropriate ICD therapy and mortality.
METHODS AND RESULTS: We identified all patients >18 years, implanted with first-time PP-ICD (n = 1873) or SP-ICD (n = 2461) in Denmark from 2007 to 2012. Co-morbidity was identified in administrative registers of hospitalization and drug prescription from pharmacies. Co-morbidity burden was defined as the number of pre-existing non-ICD indication-related co-morbidities including atrial fibrillation, diabetes, chronic obstructive pulmonary disease, chronic renal disease, liver disease, cancer, chronic psychiatric disease, and peripheral and/or cerebrovascular disease, and divided into four groups (co-morbidity burden 0, 1, 2, and ≥3). Through Cox models, we assessed the impact of co-morbidity burden on appropriate ICD therapy and mortality. Increasing co-morbidity burden was not associated with increased risk of appropriate therapy, irrespective of implant indication [all hazard ratios (HRs) 1.0-1.4, P = NS]. Using no co-morbidities as reference, increasing co-morbidity burden was associated with increased mortality risk in PP-ICD patients (co-morbidity burden 1, HR 2.1; comorbidity burden 2, HR 3.7; co-morbidity burden ≥3, HR 6.6) (all P < 0.001) and SP-ICD patients (co-morbidity burden 1, HR 2.2; co-morbidity burden 2, HR 3.8; co-morbidity burden ≥3, HR 5.8). With increasing co-morbidity burden, an increasing frequency of patients died without having utilized their device, with 72% PP-ICD and 45% SP-ICD patients with co-morbidity burden ≥3 dying without prior appropriate ICD therapy.
CONCLUSION: Increasing co-morbidity burden was not associated with increased risk of appropriate ICD therapy. With increasing co-morbidity burden, mortality increased, and a higher proportion of patients died, without ever having utilized their device.
Originalsprog | Engelsk |
---|---|
Tidsskrift | European Journal of Heart Failure |
Vol/bind | 19 |
Udgave nummer | 3 |
Sider (fra-til) | 377-386 |
Antal sider | 10 |
ISSN | 1388-9842 |
DOI | |
Status | Udgivet - mar. 2017 |
Antal downloads er baseret på statistik fra Google Scholar og www.ku.dk
ID: 193896901