Quantification of 8-oxo-7,8-dihydro-2′-deoxyguanosine and 8-oxo-7,8-dihydro-guanosine concentrations in urine and plasma for estimating 24-h urinary output

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Among markers for oxidative stress urinary excretion 8-oxo-7,8-dihydro-2′-deoxyguanosine (8-oxodGuo) and 8-oxo-7,8-dihydro-guanosine (8-oxoGuo) have been widely used in controlled and epidemiological studies, and are considered to represent intracellular markers of oxidation of DNA and RNA in the entire organism, respectively. Although being non-invasive, urinary methods have shortcomings. There is no established method for analysis of 8-oxodGuo and 8-oxoGuo in plasma and the few plasma values presented in the literature vary greatly. We here present a liquid chromatography mass spectrometry method with full validation for analysis of 8-oxodGuo and 8-oxoGuo in plasma. Further, we investigated the basis for our previously physiological model and show that a single plasma sample can be used to estimate the 24-h production of 8-oxoGuo, whereas we challenge the use of urinary 8-oxodGuo/creatinine ratio or plasma 8-oxodGuo as measures of oxidative stress.

OriginalsprogEngelsk
TidsskriftFree Radical Biology and Medicine
Vol/bind172
Sider (fra-til)350-357
Antal sider8
ISSN0891-5849
DOI
StatusUdgivet - 2021

Bibliografisk note

Funding Information:
Katja Luntang Christensen is acknowledged for her help with preparation and analysis of samples.

Publisher Copyright:
© 2021 Elsevier Inc.

ID: 273643601